Oliver Perkins CAV fuel system Questions July 09, 2020 02:31AM
Hey guys,

New to the forum but not to pulling and diesel performance.

1855 Oliver with Perkins 354.4, T4 H1E turbo, have a homebrew custom .1 pump on it. Been having issues with fuel supply, low pressure under load, running out of fuel. Still running stock filters with 7psi electric pump.

Wanting to change filter base, line size, and supply pump. Is 25psi too much for my Rotary?

Has anyone had expierence on this? Any information would be greatly appreciated.
Thanks



Edited 1 time(s). Last edit at 07/09/2020 05:51PM by BlackSheep.

Re: Oliver Perkins CAV fuel system Questions July 10, 2020 08:37AM
25 psi is just fine on a cav pump

Re: Oliver Perkins CAV fuel system Questions July 10, 2020 10:40AM
25 psi would be good for that pump maybe a holley black pump or a air dog raptor with a regulator would work good

as for filters you could get one of those filter bases like a transfer tank has and put a donaldson P551915 filter on it

Jason E.

Re: Oliver Perkins CAV fuel system Questions July 11, 2020 01:58AM
Thanks, I will look into that.