Pro field fuel and water April 11, 2021 12:01PM
Going to run pro field 466 3500 rpm.....no time for dyno run....looking for a starting ballpark fuel and water setting...13mm p pump and newer harts 3x3 thanks for any help

Re: Pro field fuel and water April 11, 2021 12:30PM
Brandon or Randy at Harts can help you with that. Just give them a call and they help you out.

Re: Pro field fuel and water April 11, 2021 12:50PM
Is this a new build? What is pump set for now? What is pump capable of pumping?

Re: Pro field fuel and water April 11, 2021 03:34PM
This should be interesting...

Re: Pro field fuel and water April 15, 2021 03:41PM
Whatever you come up for fuel, water should be about 20% of that consumption (starting place, some use more some use less). So, if you burn 1 gallon of fuel you would figure 26 oz of water. Figure you do that over a period of 10 seconds that would be 2.6oz per sec. Use that number and the pressure of your pump along with how many nozzles you're going to deploy and you can calculate the orifice size for the nozzles. It's basic rocket science, but you can do it with a calculator.

Re: Pro field fuel and water April 16, 2021 05:59AM
Every engine is different but good starting numbers for an IH:
625 to 675cc on fuel
3.0 to 3.5 oz/sec on water



Edited 1 time(s). Last edit at 04/16/2021 09:10AM by NS 1066.

Author:

Your Email:


Subject:


Spam prevention:
Please, enter the code that you see below in the input field. This is for blocking bots that try to post this form automatically. If the code is hard to read, then just try to guess it right. If you enter the wrong code, a new image is created and you get another chance to enter it right.
Message:
Website Statistics
Global: Topics: 38,580, Posts: 229,613, Members: 3,320.
This forum: Topics: 37,058, Posts: 225,861.

Our newest member Fechtner Racing