10:28:05pm, Monday, May 20, 2024
SAE Cutoff Switch
|
Registered: 01/01/2018 Posts: 66 |
We are in the process of hooking up the electronics/racepak on a mini. We have the standard SAE emergency kill with that fits to the rear of the machine that kills the tractor should it break away from the sled. We have the schematic and know the wiring but when we attempt to test the switch for continuity we get nothing. Can any of you seasoned veterans enlighten us? The switch was included with the chassis we purchased and "thought" to be good to go, but we can't get a working reading on it. Are we missing something? I hate to drop the $205 bucks on a new one unless I have too, any help would be appreciated guys. Thanks! |
Re: SAE Cutoff Switch
|
Inspector 423
|
Clean the bottom contact point, and the contact point on the pin.
Sometimes the phenolic spacer material transfers to those surfaces and a meter will not see the connection. |
Re: SAE Cutoff Switch
|
Registered: 01/01/2018 Posts: 66 |
Forrest through the trees, thanks for the slap of common sense my friend! It works fine now. |