10:17:58pm, Monday, May 13, 2024
404 combine block into 4020
|
Putting 404 from turbo 7700 combine into 4020 gas. wondering which water pump you put on? the combine pump i think will make the fan get into the radiator and the 4020 diesel water pump wont clear block. any help is appreciated
Thanks 260-609-5570 |
Re: 404 combine block into 4020
|
Registered: 07/22/2014 Posts: 197 |
Look at the water pump pulley diameters also. If I recall correctly the gas used a faster spinning size (smaller) to move more coolant. |
Website Statistics
Global: Topics: 38,747, Posts: 229,890, Members: 3,334.
This forum: Topics: 37,087, Posts: 225,994.
Global: Topics: 38,747, Posts: 229,890, Members: 3,334.
This forum: Topics: 37,087, Posts: 225,994.
Our newest member DANNY.WAINSCOTT@YAHOO.COM