09:35:57am, Sunday, May 19, 2024
Wimer pusher pump
|
Registered: 02/08/2014 Posts: 406 |
What is the proper way to adjust a Wimer pusher pump? How do you know if you're getting full fuel to the injection pump? Running an A-pump if that matters. Thanks. |
Re: Wimer pusher pump
|
Pull Fan
|
Just set it at whatever pressure that you are wanting to feed your pump with and you are good. I'm not familiar with Wimers, but I'm sure you can give them a call to get adjustment procedures for their pump. I'm sure its not super complicated? |
Re: Wimer pusher pump
|
Registered: 02/08/2014 Posts: 406 |
I talked to them about our pressure fluctuating from 50 to 70psi and didn't get a very good answer on why. They seem in a big hurry on the phone. I might have caught them on a bad day. |
Re: Wimer pusher pump
|
IH-SSD
|
Most likely has more to do with the size of your supply lines and choice of fittings. Are you running a pressure regulator check valve on your return from the pump? |
Re: Wimer pusher pump
|
Registered: 06/16/2017 Posts: 241 |
You need at least a #10 suction line on it. The one we had did the same thing. Went from an 8 to a 10 and fixed that problem for us |
Website Statistics
Global: Topics: 38,779, Posts: 229,957, Members: 3,338.
This forum: Topics: 37,098, Posts: 226,040.
Global: Topics: 38,779, Posts: 229,957, Members: 3,338.
This forum: Topics: 37,098, Posts: 226,040.
Our newest member Jacklovik2009